Gas Purification And Control Panel

GC, AAS, ICP, GCMS Gas Purification Panel

Approx Price: Rs 22,500 / Unit 

Gas Clean Filter System

GC, AAS, ICP, GCMS Gas Purification Panel

We have gained a well-known position in this market by providing an extensive range of Gas Purification Filter. Our products are completed under strict industry rule in order to preserve their adherence to worldwide accepted norms. Our clients can be purchased at industry leading prices within the prearranged time frame. In addition to this, our products are highly applauded for their strength, rust resistance and best quality.


Product Description


Our Gas Clean Filter System delivers clean gases, reducing the risks of column damage, sensitivity loss, and instrument downtime. Inserting a Gas Clean Filter System in the gas line immediately before the instrument inlet greatly reduces the level of impurities, thus improving trace analysis. Contaminants entering your GC column will also be reduced, which is critical for high temperature analysis and essential for longer column lifetime.

Replacing the filters when they have reached absorption capacity ensures maximum protection of your GC columns and analytical hardware. The sensitive indicators change color, alerting you that the filter needs to be replaced.

A Gas Clean Filter System allows you to use 99.996% (4.6) pure helium instead of the more expensive 99.999% (5.0) or 99.9999% (6.0) grade, while still yielding high quality analytical results. The expected cost savings are 30%.

Features

  • Deliver clean gases for accurate analyses
  • Fast, leak-free filter replacement reduces downtime
  • Economical, with immediate payback
  • Highly sensitive filter indicators provide maximum instrument protection
  • Fine quality
  • Perfect finish
  • Affordable rate

Gas Purification Panel

Approx Price: Rs 19,250 / Unit 
Gas Purification Panel
In our extensive product range, we are engaged in providing a quality assured range of Gas Purification Panel. This panel is used to remove oxygen, moisture, hydrocarbons, oil and other foreign materials from gas streams. The panel eliminates noise and unaccepted signals of gases in order to obtain peak resolution and peak tailing in the analysis. Our adroit workforce manufactures this panel making use of quality tested components and modern techniques according to the set industry standards.

Features:

  • Improves reproducibility of analysis
  • Reduce baseline noise, drift problems etc
  • Increase column life preferably for polar & capillary columns

Product Details:

  • The Gas Purification and Controller system is designed to remove oxygen, moisture, hydrocarbons, oil and other foreign materials from gas streams. The system eliminates noise and unaccepted signals of gases in order to obtain peak resolution and peak tailing in the analysis
  • Need for Purification panel in Gas Chromatography has been realized now beyond any doubts both for the column & the detector. As a number of problems in Gas Chromatographic analysis are caused by impure gases, the gases used in the GC have to be pure and free form Oxygen Hydrocarbon and moisture as they are harmful to GC. The hydrocarbons present may give baseline noise and irreproducible results. Moisture and oxygen can strip phase, case excessive bleed thus damaging the GC column or shorten its span
  • The Gas Purification and Controller system is designed to remove oxygen, moisture, hydrocarbons, oil and other foreign materials form gas streams. The system eliminated noise and unaccepted signals of gases in order to obtain peak resolution and peak tailing in the analysis. The carrier gas passes through oxygen and moisture removal filters and passes through moisture and hydrocarbons removal filters and hydrogen passes through moisture removal filter. All gas streams are controlled by a constant pressure regulator, the inlet ad outlet pressure being displayed on gauge. The system is wall mounted

Specifications:

  • Compact design, wall mounted, powder coated
  • Deliver Ultra high pure (UHP) grade gases
  • Filters are easily detachable
  • Suitable for 10 kg/cm2 inlet pressure & 7 kg/cm2 Outlet pressure Deliver Ultra high pure (UHP) grade gases
  • 1/4" or 1/8" fittings & tubing’s for each line
  • Custom made Gas filter station can be made as per order 1/4" or 1/8" fittings
  • Gas Purification Panel is used in Gas Chromatograph for FID, TCD, ECD, ICP, MS, and AAS

Benefits:

  • Improves reproducibility of analysis
  • Reduce baseline noise, drift problems etc
  • Increase column life preferably for polar & capillary columns
  • Deliver better than UHP grade gases
  • Increase detector life & reduces flame problem
  • Save costly gases through toggle valves & gas distribution panel

Additional Information:
  • Minimum Order Quantity: 1 Unit

Gas Purification Panel for ICP

Approx Price: Rs 19,500 / Unit 
Gas Purification Panel for  ICP
We are a renowned name in the industry to offer our patrons a premium quality range of Gas Panel for AAS, ICP, GCMS. The offered panel is widely used in various industries for numerous purposes. Using quality approved components with the aid of contemporary methodology; the provided panel is exclusively manufactured at our sound production unit under the stern surveillance of qualified technocrats. For its unique features like easy usage and high functioning, the offered panel is highly demanded by precious clients.

Features:

  • Compact design, wall mounted, powder coated
  • Deliver Ultra high pure (UHP) grade gases
  • Filters are easily detachable

 Gas Clean Filter indicators are more sensitive:

  • With the Gas Clean Filter System, you can be completely confident that your gas supply contains less than 0.1 ppm of moisture. The system will not suffer from hydrolization damage, saving you expense and needless downtime in replacing degraded components. Our moisture filters offer unsurpassed protection against moisture contamination for your GC system.


A full range of filters:


  • Six different fi lters are available. Each fast-stabilizing absorbent is packed in a transparent and virtually unbreakable, heavy-walled polycarbonate housing. Our full range offers you:
  • A GC/MS Filter that delivers faster stabilization times for lower gas consumption and faster set-up time. The single filter unit with a combination of fi lters removes oxygen, moisture, and hydrocarbons from carrier gas for MS applications.
  • A Moisture Filter that also delivers faster stabilization times for increased productivity in GC. Water removal prevents needless hydrolization damage to the stationary phase, fused silica surface, glass wool, or septum.
  • An Oxygen Filter that prevents oxidation of the liquid stationary phase, septum, or glass wool in GC.
  • A Process Moisture Filter, process connecting units, and male connectors, free from any brass and copper, for safe use with acetylene in process GC.
  • A Charcoal Filter that removes organic compounds and ensures correct performance of FID detectors in GC.
  • A new Carbon Dioxide Filter that eliminates CO2 from supply gas. When combined with a Moisture Filter, it is ideal for zero-air gas generators.
  • Improvements to the absorbance materials in the GC/MS and Moisture Filters mean that they stabilize more quickly to reduce downtime and improve productivity. We have also
  • introduced a high flow connection unit that handles flow rates up to 20 L/min for collision gas applications, supply gas for ICP and ICP-MS, or any application where high flows are required, expanding the range of applications you can run. For operations requiring flows above 10 L/min, you can save money by using cheaper gas and by eliminating contaminants.
  • Each Gas Clean Filter is compatible with both the high flow and standard connection units.
  • All GC applications benefit from the use of Gas Clean Filters, whether your GC is connected to an FID or MS or to any other type of detector, such as flame photometric, thermal conductivity, electron capture, nitrogen-phosphorous, or thermionic.

Additional Information:
  • Minimum Order Quantity: 1 Unit

Gas Purification and Control Panel

Approx Price: Rs 22,500 / Unit 
Gas Purification & Control Panel

Salient Features

  • Deliver Ultra High Pure (UHP) Grade Gases
  • Compact Design, Wall Mounted, Powder Coated
  • Filters are easily detachable
  • Suitable for 10kg/cm² inlet pressure & 7 kg/cm² outlet pressure
  • Panel for LC-MS-MS & other applications are also available

Benefits for GC:


  • Reduce baseline noise, drift problems, etc.
  • Increase column life, GC detectors & reduces flame problems
  • Improve reproducibility
  • Save costly gases through toggle valves & gas distribution panel.

Gas Distribution Panel

Gas distribution panel is used when there is more than one Gas Chromatograph. It helps to controlled the flow & pressure of different gases for different GC's. Gas distribution panels are available in three different types. One is with pressure gauge (to indicate pressure), pressure regulator (to control pressure), ON/OFF valve (to isolate). Second with pressure gauge and ON/OFF valve. Third is with only ON/OFF valve.

Gas Selector Box

Gas Selector Box is used for the selection between two gases of different types. Two types of gas selector box available one with selector valve, pressure gauge & toggle valve, another with only two toggle valve.

Additional Information:
  • Minimum Order Quantity: 1 Unit

Gas Purification System

Approx Price: Rs 22,500 / approx 

Gas Clean Filter


The Gas Purification System features include:


  • Easy to replace Cartridges
  • High capacity
  • Wall bracket gets the system up and out of the way

 

This system will provide in-line contaminant removal for your GC gases. This system has convenient replaceable cartridges with a visual indicator.

 

The Athena Gas system consists of three cartridges in series to reduce column damaging impurities. The first cartridge in the system will remove residual hydrocarbons and water from the carrier gas stream. The second cartridge provides high-capacity oxygen removal (capacity is least 1000 cc of pure oxygen); the third cartridge contains an inorganic indicator that changes from light green to gray to provide warning when the high-capacity oxygen trap is depleted. All systems are helium leak tested after assembly. Approximate dimensions: 33 cm W x 33 cm H x 8 cm D; weight 4 kg.


Additional Information:
  • Minimum Order Quantity: 1 approx

Gas Distibution and Control Panel

Approx Price: Rs 9,500 / Unit 
Gas Purification and Control Panel

Fostered with rich industry knowledge and an extremely accomplished team of professionals, we are offering Gas Purification Panel. These panels are used to remove the vapors impurities like CO, CO2, moisture, hydrocarbon from argon & acetylene, N2O. Our offered panels are manufactured at our manufacturing unit using quality permitted material. By our quality coordinators these panels are checked on a variety of quality limits.

Features:

  • Compact Design
  • Wall Mounted
  • Powder Coated

we are offering an all-embracing array of Gas Purification Panel. As per the industry guiding ethics, we manufacture these purification panels using quality protected material and present-day technology. Also, our quality managers keep an eye on these purification panels at every step of manufacturing in order to eliminate any possible fault from.

Features:
GPP-01

  • Industry proven design
  • Sturdiness
  • Simple to install
Gas Purification for AAS & ICP-MS is Optional one can also used gas distribution panel instead of gas purification panel.

Product Details:
  • Deliver Ultra High Pure (UHP) Grade Gases
  • Filters are easily detachable
  • Suitable for 10kg/cm2 inlet pressure & 7 kg /cm2 outlet pressure
  • Panel for LC-MS-MS & other applications are also available
  • Advantages of Gas Purification panel
  • Reduce baseline noise, drift problems, etc
  • Increase column life, GC Detectors & reduces flame problems
  • Improve reproducibility
  • Save costly gases through toggle valves & gas distribution panel
  • For Installation Diagram

Using the best grade material, we are successfully manufacturing, trading and supplying a broad gamut of Gas Purification Panel.Offered purification panels are meticulously checked under the instructions of our competent professionals on a number of parameters of quality to give statement to our clients that these purification panels are the unmatched in terms of quality. These purification panels are applauded in the market for their industry accepted finish.

Features:

  • Finely finished
  • Enhanced durability
  • Precision-designed

Product Details:

  • The Gas Purification and Controller system is designed to remove oxygen, moisture, hydrocarbons, oil and other foreign materials from gas streams. The system eliminates noise and unaccepted signals of gases in order to obtain peak resolution and peak tailing in the analysis
  • Need for Purification panel in Gas Chromatography has been realized now beyond any doubts both for the column & the detector. As a number of problems in Gas Chromatographic analysis are caused by impure gases, the gases used in the GC have to be pure and free form Oxygen Hydrocarbon and moisture as they are harmful to GC. The hydrocarbons present may give baseline noise and irreproducible results. Moisture and oxygen can strip phase, case excessive bleed thus damaging the GC column or shorten its span
  • The Gas Purification and Controller system is designed to remove oxygen, moisture, hydrocarbons, oil and other foreign materials form gas streams. The system eliminated noise and unaccepted signals of gases in order to obtain peak resolution and peak tailing in the analysis. The carrier gas passes through oxygen and moisture removal filters and passes through moisture and hydrocarbons removal filters and hydrogen passes through moisture removal filter. All gas streams are controlled by a constant pressure regulator, the inlet ad outlet pressure being displayed on gauge. The system is wall mounted

  • used in Gas Chromatograph for FID, TCD, ECD, ICP, MS, and AAS

Additional Information:
  • Minimum Order Quantity: 1 Unit

Gas Clean Filter

Approx Price: Rs 1,550 / Unit 
Product Details:
  • Minimum Order Quantity: 1 Unit
  • Filter Type: Activated Carbon Filters, Oxytrap Filter

Gas Clean Filter
Specification


  1. Oxytrap Filter
  2. Moiture Filter
  3. Charcoal Filter
  4. GCMS Filter
  5. CO2 Filter

Specification:


Description

Oxygen Filter

Moisture Filter/Process Moisture Filter

Charcoal Filter

GC/MS Filter

CO2 Filter

Function

Removes oxygen as well as traces of sulfur and chlorine compounds from carrier gas

Removes water, oil, and other foreign material from the carrier gas

Removes organic compounds from gas streams

Single combination filter; removes water, oxygen, and organic compounds

Removes CO2 from gas stream; to be used in combination with Moisture Filter

Indicator color change

From green to gray

From green to pale brown

No indicator

Oxygen: from green to gray Moisture: from green to pale brown

From white to violet

Capacity

150 mL oxygen

7.2 g water

Approximately 7 g, depending on impurities

100 mL oxygen, 1 g water, organics depending on impurities

9 g CO2

Outlet concentration at operating flow of 1-10 L/min

<50 ppb

<0.1 ppm

<0.1 ppm

Oxygen <50 ppb Moisture <0.1 ppm Organics <0.1 ppm

<1 ppm

Gas Distribution Panel

Approx Price: Rs 9,500 / Unit 
Gas Distribution Panel

Keeping in mind the precise demands of our treasured patrons, we supply Gas Distribution Panel. This product range is completed at advanced premises using quality approved raw material in compliance with worldwide quality standards. In order to meet the worldwide quality standards, the entire range is stringently tested on different parameters. Furthermore, this range is available at inexpensive rates for our precious customers.


Features:


  • Longer working life
  • High performance
  • Maintenance free

Additional Information:
  • Minimum Order Quantity: 1 Unit

GC Filters Traps

Approx Price: Rs 1,550 / Unit 
Product Details:
  • Minimum Order Quantity: 1 Unit
  • Brand: Athena

GC Filters and Traps Protect your instrument and capillary column/ technical results with the correct high-quality gas filtration system.

We have a wide assortment of filters that remove moisture, oils, dust, hydrocarbons, oxygen, sulfur compounds and more. Select the proper filter for your application needs.

Advanced Filter System

  • Two indicators – for oxygen and moisture
  • Gas contacts only metal, fluoroelastomer and glass
  • High capacity and efficiency in a single cartridge
  • Easy cartridge replacement with on/off knob
  • Double-seal construction for safety
  • Check valves protect gas lines during cartridge replacement
  • Includes mounting hardware for bench or wall
  • The Advanced Filter System has high-capacity and efficiency levels for oxygen, water and hydrocarbons.The recommended maximum flow rate is 2 L/min with 200 psi maximum operating pressure.
  • Capacity EfficiencyOxygen 850 cc <1 ppbWater 12 g <10 ppbHydrocarbons 8 g <1 ppbA polycarbonate shield surrounding the glass indicator section of the filter is sealed, unlike othergas filters, the gas flow is secure even if the glass should break. This redundant sealing system androbust construction provides a new level of security in gas filtration.

Three-Cartridge Gas Purification System

  • All-Stainless Steel Cartridges are easy to replace
  • High capacity
  • Wall bracket gets the system up and out of the way Capacity Efficiency Oxygen 1000 cc <1 ppbWater 25 g <30 ppbHydrocarbons 19 g <1 ppb (C5 and higher)This system provides for high-capacity contaminant removal for GC supply gases, and allows for individual cartridge replacement. Cartridge replacement is recommended after processing 19 cylinders of 8 m3 high purity gas (99.997%).

Gas Selector Box

Approx Price: Rs 5,500 / Unit 
Gas Selector Box

Description:


  • Gas Selector Box is used for the selection between two gases of different types.
  • Two types of gas selector box available one with selector valve, pressure gauge & toggle valve, another with only two toggle valve.

Standard system consists of a panel incorporating gas controls and purification traps for four gases in a unit, namely, Nitrogen, Helium, Hydrogen and Zero Air. Frequent changeover of carrier gas from Helium to Nitrogen is required for certain Gas Chromatographic applications. Hence, Gas Selector Box is used for the selection between two gases of different types. This uses a special Gas Sampling Valve which takes care of leakage problems especially faced while using Helium.

Two types of gas selector box are available one with selector valve, pressure gauge & toggle valve, another with only two toggle valve.

Additional Information:
  • Minimum Order Quantity: 1 Unit

Gas Purification Panel for Chromatography

Approx Price: Rs 22,200 / Unit 

Gas Clean Filters for Chromatography, ICP, and TOC

  • Delivering Clean Gases For Accurate Analyses
  • Enhanced gas quality for maximum productivity
  • The Athena Gas Clean Filter System delivers clean gases, reducing the risks of column damage, sensitivity loss, and instrument downtime.
  • Contaminants in gases can signifi cantly affect your analysis. Oxygen, hydrocarbons, and moisture can cause loss of sensitivity and accuracy of the GC and damage your column.
  • Impurities activate glass wool in liners and accelerate septa degradation, causing high background signals and ghost peaks and leading to time-consuming troubleshooting.
  • Oxygen in the supply gas for ICP-OES or ICP-MS can cause plasma shut-down and loss of sensitivity. Carbon dioxide in supply gas for TOC analyzers causes elevated baselines and loss of sensitivity and accuracy.

 

Supply gases can pick up contaminants from every part of the gas line. You therefore need a Gas Clean Filter System even if your supply gas is of the highest quality – it is not economical to buy expensive, high purity gases if their quality is downgraded by impurities in the gas line.

 

  • GC/MS Filter – provides faster stabilization times to reduce gas consumption
  • Moisture Filter – delivers faster stabilization times for increased productivity in GC
  • Process Moisture Filter and connecting unit – designed for use with acetylene in process GC
  • Carbon Dioxide Filter – eliminating CO2 from supply gas, to minimize loss of sensitivity and improve accuracy in TOC
  • High flow connection unit – for applications up to 20 L/min
  • Brand: Athena
  • Model:  ATG-01
  • Application: Laboratory Use,  Pharmaceutical

Additional Information:
  • Minimum Order Quantity: 1 Unit
Looking for Gas Purification And Control Panel ?
© Athena Technology
 